Habitest - Electrical Stimuli

ELECTRICAL STIMULI (SHOCKERS)

H13-15 : Precision Animal Shocker (Manual settings only)
H13-16 : Precision Regulated Animal Shocker (Manual and Programmable settings)
A13-16 : Shock Level Tester

SHOCKER CABLES

H93-01-25 : 25 ft. Shock Cable – 8-Conductor (For H13-16)
H93-01-50 : 50 ft. Shock Cable – 8-Conductor (For H13-16
H93-13-32 : 32 in Jumper Cable – 8-Conductor (For H13-16)
H93-19-25 : 25 ft. Shock Cable – 2-Pole / Universal Clips (For H13-16)
H93-19-50 : 50 ft. Shock Cable – 2-Pole / Universal Clips (For H13-16)
H93-30 : Shock Distributor Board For Rat Hub / Runway
H93-31-32 : 32 in. Shock Distributor Cable For Rat Hub / Runway

 

H13-15 : Precision Animal Shocker (Manual settings only)

H13-15: Precision Regulated Animal Shocker (Manual)

This research grade, precision feedback, current-regulated shocker is totally isolated (floating output) for operator and subject safety, as well as isolation from other sources of electrical stimulation such as physiological stimulators that may be in use concurrently. Isolation is achieved by using an isolated transformer along with optical isolation of the inputs from the control equipment.

The unit can function as a two-pole (bipolar) current reversal "square wave" output, or as a scanner distributing the polarity reversal across an 8-pole output for grid floor applications. Mode selection is made by a switch on the back.

The grid outputs are direct "Form C" semiconductor switches. The "off" grids have zero resistance so the subject receives the same current regardless of the number of grids contacted.

 

H13-16 : Precision Regulated Animal Shocker (Manual and Programmable settings)

H13-16: Precision Regulated Animal Shocker (Manual & Programmable)

This research grade, precision feedback, current-regulated shocker is totally isolated (floating output) for operator and subject safety, as well as isolation from other sources of electrical stimulation such as physiological stimulators that may be in use concurrently. Isolation is achieved by using an isolated transformer along with optical isolation of the inputs from the control equipment.

The unit can function as a two-pole (bipolar) current reversal "square wave" output, or as a scanner distributing the polarity reversal across an 8-pole output for grid floor applications. Mode selection is made by a switch on the back.

The H13-16 may be programmed from 0 to 5 milliamps in 20 microamp increments by a 0-2.5 Volt signal via the Programmable. Input on the back of the case. The signal is generated by the Graphic State Notation control program and comes from the Programmable. Output on the back of the Habitest Linc or you may also use a D/A converter output.

The grid outputs are direct "Form C" semiconductor switches. The "off" grids have zero resistance so the subject receives the same current regardless of the number of grids contacted.

The H13-16 may be programmed from 0 to 5 milliamps in 20 microamp increments by a 0.2.5 volt signal via the "Prog. Input" on the back of the case. The signal is generated by the Graphic State Notation control program and comes from the "Prog. Output" on the back of the Habitest Linc (you may use your own D/A converter output).

Power On/Off Switch: On rear panel
Remote/Manual Operate: Up - enables an external signal to operate the shocker; Center - disables remote operate; Down - operates shocker manually for duration of depression.
Remote Operate: Turns shocker on when external 5 to 30 volt signal is applied.
Meter Range Switch: 5-position switch selects meter range.
Manual-Set Shock: Set shock manually while reading the meter.
Shock Routing: Set Test Routes shock to a dummy load for setting or to subject.
Max Prog. Control V In: (0-2.5 volts input, 0-5 milliamps output).
Max. Output Current: 5 milliamps into 75K Ohms
Max. Output Voltage: 500 volts
Calibrate Load: 50K Ohms
Regulation: At 500 microamps - 2% at 0 to 900K Ohms,
     at 1 milliamp - 2% at 0 to 450K Ohms
     at 2 milliamps - 2% at 0 to 225K Ohms
AC Switching: Zero Crossover
Indicators: Power On, Shock Test Load, Shock Subject
Dimensions: 255mm W x 178mm D x 83mm H
Electrical: 110/120 VAC 50-60 Hz or 220/240 VAC 50-60 Hz (specify on order)

 

A13-16 : Shock Level Tester

A13-16: Shock Level TesterThe A13-16 Shock Level Tester allows for verification of the shock output of a shock source. This unit requires a Volt Meter and/or Oscilloscope (not included). The input jack connects to alligator clips (included) that can easily be attached to either subject electrodes or the grids of a shock floor.

This unit provides two output options for verification. The first is a rectified DC output that can be used with any standard volt meter. This output will be consistent with Ohms Law, V (volts) = I (amps) * R (ohms), where the internal resistance load used is 10 kilohms. Because this output circuit contains diodes and filtering, the voltmeter output will be slightly lower than predicted.

In order to meet the requirements of more rigorous verification, the second output provided is for connection to an oscilloscope. This output will follow ohms law precisely. The maximum amplitude of the output pulse will be exactly equal to Ohms Law.